Compressors › Breathing Air Compressor › Gas Compressor ›› Helium Compressor ›› Nitrogen Compressor ›› Argon Compressor › Industrial Air Compressor ›› Piston Type Compressor ›› Screw Type Compressor Valves › Ball Valve › Gate Valve › Butterfly Valve › Float Valve › Angle Valve › Handle Valve › Check Valve › Pressure Reducing Valve › PICV › Commissioning / DRV › Thermostatic Mixing Valve › Actuator Valve › Strainer Pumps › Surface Type Pumps › Submersible Pumps › Circulation Pumps Skid Systems › Booster Pump Set › Lifting Pump Set › Circulation Pump Set › Fire Pump Set › Chilled Water Pump Set › Central Water Heating & Cooling System Copper Pipes & Fittings › Table X › Table Y › Coated Table X › Coated Table Y › Compression Fittings › Brazing Fittings › Solder-Ring Fittings
Electrical & Instrumentation
Transformers › Dry Type Transformer › Oil Type Transformer › Special Type Transformer Explosion Proof Solutions › Explosion proof enclosures (Ex d) › Explosion proof Junction boxes (Ex d) › Explosion proof junction boxes (Ex e) › Explosion proof control stations (Ex d) › Explosion proof control panels (Ex d) › Explosion proof glands (Ex d) › Explosion proof panel accessories (Ex d) Switchgears › MV Switchgear › LV Switchgear ›› Power distribution Centers ›› Motor Distribution Centers ›› Special Application ›› Utility Sector ›› Power Factor Correction Centers Smart Meters Instrumental Transformers › Current Transformers ›› MV Current Transformers ›› LV Current Transformers › Potential Transformers ›› MV Potential Transformers › Instrumental Transformers Cable Accessories › Heat shrinkable Joints and termination kits › Screened Separable Connector › Pre-Moulded Joints and Terminations Motor Control Panels › Booster Pump Control Panels › Lifting Pump Control Panels
Safety
Gas Detection System › Portable Gas Detectors › Fixed Gas Detectors ›› Wired Detectors ››› Toxic ››› Flammable ››› Hydrogen Gas ››› Open Path ››› Flame Detectors ›› Wireless Detectors Breathing Apparatus Gas Fire Fighting System Suspend Gas Fire Fighting Modules
Contact

Cylindrical gas fire fighting modules

Modules and batteries for automatic gas fire extinguishing, designed for long-term storage and release of gas extinguishing agent.

ASKU: ASKU-GFF-CGF-001

Description

Modules and batteries for automatic gas fire extinguishing, models: MPGT – 40 “SMD” (65-40-32), MPGT – 50 “SMD” (65-50-32), MPGT – 60 “SMD” (65-60-32), MPGT – 70 “SMD” (65-70-32), MPGT – 80 “SMD” (65-80-32), MPGT – 90 “SMD” (65-90-32), MPGT – 100 “SMD” (65-100-32), MPGT – 120 “SMD” (65-120-32), MPGT – 80 “SMD” (65-80-50), MPGT – 100 “SMD” (65-100-50), MPGT – 120 “SMD” (65-120-50), MPGT – 140 “SMD” (65-140-50), MPGT – 150 “SMD” (65-150-50) (hereinafter referred to as modules), as well as batteries that include the same type of MPGT modules and are connected by a common collector (hereinafter referred to as batteries).

According to the method of storage, GFFS are divided into modular and centralized (a group of modules assembled into a battery and connected to a common manifold). Modules and batteries refer to components of automatic fire extinguishing systems and are used for storing GFFS with a further automatic or remote or local launch method when class fires occur A, B, and E electrical equipment with a voltage not higher than permissible for a gas fire extinguishing agent.

Modules and batteries are operated and operational at ambient temperatures from minus 20°C to plus 50°C, climatic version UHL (NF) category 4, atmosphere type II, III according to GOST 15150-69.

Modules and batteries are manufactured in accordance with the requirements of these technical specifications TU 26.30.50-771-81888935-2023 “Modules and batteries for automatic gas fire extinguishing”, EAEU TR 043/2017 “On requirements for fire safety and fire extinguishing means”, SP 485.1311500. 2020, GOST R 53281-2009, GOST 12.2.003-91, GOST 12.2.007.0-75, GOST 12.3.046-91, GOST 15150-69 vessels used for storing GFFS must meet the requirements of TR CU 032/2013 Technical Regulations of the Customs Union “On the safety of equipment operating under excess pressure” according to design documentation approved in the prescribed manner.

Highlights

  • The modules are designed for long-term storage and release of gas extinguishing agent in the event of a fire in a building (premises) or structure.
  • A group of modules combined into a single battery is intended for the centralized storage of a large volume of fire fighting fuel with the subsequent release of fire fuel in the event of a fire in large areas.
  • The modules are used to extinguish class A, B and E fires of energized electrical equipment.
  • The method of storing GFFS is modular or centralized.
  • The batteries have the ability to be connected to a single pipeline manifold, forming a centralized GFFS storage point.
  • Modules and batteries are used for fire protection of premises and equipment in a modular design for volumetric or local volumetric fire extinguishing.
  • Modules and batteries are classified as recoverable and serviceable technical products.
  • The design of modules and batteries meets the seismic resistance requirements in accordance with GOST 30546.1-98, GOST 30546.2-98 and GOST 30546.3-98 and has a design of 9 points on the MSK-64 scale.
  • Service life from the date of manufacture is no more than 30 years.

Engineered for maximum reliability, our cylindrical gas fire fighting modules provide critical infrastructure protection across industrial zones in Qatar. We supply highly durable suppression cylinders designed to seamlessly integrate with centralized extinguishing systems for large-scale safety compliance.